x
uploads/perchlorate.jpg

perchlorate n.【化學】過氯酸鹽。 perchlorate expl...

perchloric

The response of the glucose electrode is surveyed by determining cyclic voltammetric peak current values under aerobic solution conditions . electrocatalytic oxidation of glucose at the electrode is evaluated with respect to temperature , ph value of solution and concentration of tris ( 2 , 2 ' - bipyridyl ) cobalt ( iii ) perchlorate 實驗用循環伏安法測定有氧溶液條件下葡萄糖在該生物傳感器上產生的催化氧化峰電流,考察了溫度、溶液ph值和co ( bpb濃度對傳感器的電流響應性能的影響。

The obtained biosensor exhibits high sensitivity , excellent reproductivity and good stability with substantially improved performance . part two describes the manufacture and characterization of glucose oxidase - silver sol - polyvinyl butyral modified platinum electrodes with tris ( 2 , 2 ' - bipyridyl ) cobalt ( iii ) perchlorate as an electron transfer mediator in the glucose solution 用納米ag溶膠固定god ,采用聚乙烯醇縮丁醛為輔助固酶膜基質修飾鉑絲電極,并以葡萄糖溶液中的co恤pyh ( cio4 ) 3為電子媒介體組成葡萄糖氧化酶生物傳感器。

In order to overcome this drawback , the electron transfer mediators were explored , we select nathpol green b , azure , tris - 2 , 2 ' - dipyridylcobalt ( iii ) perchlorate trihydraie in glucose solution as electron transfer mediators to improve the glucose biosensor ' s sensitivities and linear scope 為了克服這個缺點,本文分別采用具有電活性的萘酚綠、天青、以及合成的co ( bpy ) _ 3 ( clo _ 4 ) _ 3放入測試底液中作為電子媒介體,提高葡萄糖傳感器的靈敏度和線性范圍。

The author developed a new method for the determination of potassium perchlorate content . as compared with the industry standard : hg3247 - 2000 , the new method is not only precise but also accuracy 摘要建立一種高氯酸鉀含量測定的新方法,較之行業標準hg3247 - 2000中高氯酸鉀含量的測定方法不僅精密度好、準確度也高。

Unfortunately , the solid propellants ? usually aluminum fuel and ammonium perchlorate oxidizer ? burn fairly inefficiently , are toxic to the environment , and are difficult to fabricate and handle safely 然而固體推進劑(通常是鋁燃料和過氯酸銨氧化劑)燃燒效率頗低、對環境有害,而且很難安全地制造和操作。

Characterization of air quality - stationary source emissions - method for the determination of the mass concentration of sulphur dioxide : hydrogen peroxide barium perchlorate thorin method 空氣質量表征方法.第4部分:固定排放源.第1節:二氧化硫質量濃度測定方法:過氧化氫高氯酸鋇釷試驗法

Application of ion chromatography in the analysis of disinfection by - products and perchlorate in drinking water was reviewed 摘要介紹了離子色譜在飲用水中消毒副產物及高氯酸鹽分析中的應用。

Synthesis and characterization of the complexes of lanthanide perchlorates with n , n ' - dimethyl - n , n ' - diphenyl - 3 , 6 - dioxaoctane diamide 三甘雙酰氮甲基苯胺稀土高氯酸鹽配合物的合成及表征

The methods for the determination of bromate and perchlorate with ion chromatography were discussed emphatically 重點介紹了離子色譜測定飲用水中溴酸鹽和高氯酸鹽的方法。

Manufacturer of electrolytic chemicals in china , producing a range of chlorates , perchlorates , and persulfates -生產銅鹽鎳鹽化纖油劑醫藥中間體和染料中間體。

Thermochemical study of a mixed ligand complex of lanthanum perchlorate with glycine and l - alanine 高氯酸鑭和甘氨酸及丙氨酸混配型配合物的熱化學研究

Influence of er3 to luminescence of samarium perchlorate with diphenyl sulfoxide coordination compounds 對二苯亞砜高氯酸釤配合物發光的影響

Lithium perchlorate anhydrous 無水高氯酸鋰

Sodium perchlorate monohydrate 一水化鈉高氯酸鹽

Potassium perchlorate for industrial use 工業高氯酸鉀

Perchlorate related environmental problems 高氯酸鹽的環境污染問題

Expressions of collagen in lung of rats exposed to ammonium perchlorate 型膠原表達的體外研究

The process provides a facile way of producing hydrocarbl perchlorate from alkenes, cycloalkenes, aralkenes, alkanols, cycloakanols and aralkanols . 本文介紹了從鏈烯、環烯、芳鏈烯、鏈烷醇、環烷醇、芳烷醇來制備過氯酸烴基酯的方便方法。

Differential thermal analysis did not reveal the ammonium perchlorate phase change from rhombic to cubic . 差熱分析沒有測出過氯酸銨從正交晶向立方晶的相變。